기간 미지정 시 최근 24시간 조회
[mysql_db] tb_machine 조회
1
NO mysql_db pt_idx mysql_db cp_idx mysql_db mc_idx mysql_db mc_iot_mac mysql_db mc_motor_kw mysql_db mc_motor_rpm mysql_db mc_motor_hz mysql_db mc_acc_sec mysql_db mc_dec_sec mysql_db mc_min_hz mysql_db mc_risk_press mysql_db mc_taget_press
12544425505123194:3C:C6:C1:4B:5F7.5360024030308077

추가 분석 테이블 : SOL_ONLYLOAD_AVGKW 기준 EST_HZ / EST_RPM 계산
선택 모터 종류 : 삼상 유도 모터
정격점(mysql 참조) : KW=7.5000, HZ=240.0000, RPM=3,600.0000
보정 파라미터 : ALPHA=0.4000, GAMMA=0.8000, MAX_RATIO=1.0000
계산식
motor_type      = induction
[1] linear_ratio    = SOL_ONLYLOAD_AVGKW / rated_kw
[2] nonlinear_ratio = pow(linear_ratio, 0.8)
[3] final_ratio     = (1-0.4)*linear_ratio + 0.4*nonlinear_ratio
[4] EST_AVGHZ             = rated_hz * final_ratio
[5] EST_AVGRPM            = rated_rpm * final_ratio
공식 기반 모터 커브 차트
선택 모터 : 삼상 유도 모터 / rated_kw=7.50kW, rated_hz=240.00Hz, rated_rpm=3,600RPM / alpha=0.40, gamma=0.80
공식 : final_ratio = (1-alpha)*linear_ratio + alpha*pow(linear_ratio, gamma) / X축=Hz 또는 RPM, Y축=kW
HZ 기준 커브 : X=Hz / Y=kW
RPM 기준 커브 : X=RPM / Y=kW
비율 커브 : KW 증가에 따른 linear / nonlinear / final ratio
조회 row 개수 : 21 / 현재 페이지 : 1 / 1 / 페이지당 50개
NO time MAC ONLY_AVGKW SUM_AVGKW REAL_AVGHZ REAL_AVGRPM EST_RATIO EST_AVGHZ EST_AVGRPM AVGPRESS pressure1 sol_run_status power_consumption 그래프
12026-07-28 11:52:2594:3C:C6:C1:4B:5F1.55.7699990.2354568476.16.505.7
22026-07-28 11:51:2494:3C:C6:C1:4B:5F5.46.2731,0770.73691772,6534.95.106.2
32026-07-28 11:50:2394:3C:C6:C1:4B:5F0.05.2669890.0000006.36.005.7
42026-07-28 11:49:2394:3C:C6:C1:4B:5F0.05.6659870.0000006.56.405.7
52026-07-28 11:48:2394:3C:C6:C1:4B:5F5.16.0711,0480.70531692,5395.06.505.7
62026-07-28 11:47:2194:3C:C6:C1:4B:5F6.26.2731,0830.84122023,0284.74.706.3
72026-07-28 11:46:2194:3C:C6:C1:4B:5F4.95.1701,0370.68091632,4514.74.806.2
82026-07-28 11:45:2194:3C:C6:C1:4B:5F0.00.03540.0000004.44.800.2
92026-07-28 11:28:1894:3C:C6:C1:4B:5F0.05.6669920.0000005.75.805.7
102026-07-28 11:27:1894:3C:C6:C1:4B:5F0.05.8659830.0000005.75.805.7
112026-07-28 11:26:1794:3C:C6:C1:4B:5F5.46.1741,0560.74361782,6774.66.105.7
122026-07-28 11:25:1694:3C:C6:C1:4B:5F4.74.9701,0140.65381572,3543.13.206.2
132026-07-28 11:24:1594:3C:C6:C1:4B:5F0.00.00720.0000001.13.200.0
142026-07-28 10:44:4694:3C:C6:C1:4B:5F0.82.1527980.1291314654.94.700.0
152026-07-28 10:38:2094:3C:C6:C1:4B:5F0.02.6548230.0000005.65.000.3
162026-07-28 10:25:3094:3C:C6:C1:4B:5F0.05.4598860.0000005.75.705.3
172026-07-28 10:24:2894:3C:C6:C1:4B:5F0.05.2578500.0000005.75.805.2
182026-07-28 10:23:2894:3C:C6:C1:4B:5F0.05.3609020.0000005.95.905.3
192026-07-28 10:22:2894:3C:C6:C1:4B:5F2.95.6649530.42311021,5235.36.005.2
202026-07-28 10:21:2694:3C:C6:C1:4B:5F4.74.9659610.65101562,3444.14.405.8
212026-07-28 10:20:2694:3C:C6:C1:4B:5F0.00.0101690.0000003.14.400.3

추가 분석 테이블 2 : sol_run_status = 1(안정구간) / ONLY_AVGKW 높은순 TOP 15
대상 row 개수 : 0 / 표시 : 0개
NO time MAC ONLY_AVGKW SUM_AVGKW REAL_AVGHZ REAL_AVGRPM EST_RATIO EST_AVGHZ EST_AVGRPM AVGPRESS pressure1 sol_run_status power_consumption 그래프
조회 결과가 없습니다.
테이블 2 차트 : TOP15 데이터를 시간순으로 표시
표시항목 : ONLY_AVGKW / SUM_AVGKW / REAL_AVGHZ / EST_HZ / power_consumption
×

장비 제어
MAC 주소가 반드시 1개 있어야 합니다.
현재 MAC : 94:3C:C6:C1:4B:5F